Discounts and more: follow LNG-DRIVE on Facebook to get updates about interesting promotions and news. 

Instructions LNG DRIVE Kallo

 
kallo.jpg

LNG DRIVE KALLO
STEENLANDLAAN 3, Haven 1111
9130 KALLO
+32 (0)800 99 903
24/7

payments-all.png
 

Drivers should be specially trained to be allowed to tank LNG safely. Reservations for a free on-site training: tel. 0800 999 03.

 
01.jpg

1. Park

p1.png
  • Park vehicle in the correct position.

  • Filling point should be aligned with white line.

  • Shut off the engine

  • Close vehicle doors and windows


02new.jpg

2. Precautions

p2.png
  • No smoking or open fire allowed.

  • Please don’t use your cell phone.

  • Wear long pants, long sleeves and closed shoes.

  • Wear thermo gloves.

  • Wear safety glasses (or a face shield).


03.jpg

3. Preparation

p3.png

Remove dust cap from filling connection (and gas return connection if needed)

  1. Filling connection

  2. Gas return connection


LNG-4-new.gif

4. Clean the filling nozzle

p4.png

Remove any moisture from the filling nozzle with compressed air.


LNG-6-new-2.gif

5. Connect the filling nozzle

p5.png

Carefully connect the filling nozzle with the vehicle tank. Push the 2 levers forward to lock the nozzle onto the tank.


LNG-7-new.gif

6. Check and adjust pressure if needed

  • If pressure of tank is below 10 bars, proceed to step 8

  • If pressure is more that 10 bars, connect vent hose to the vehicle tank by turning the bayonet connection until it locks. Open the gas venting valve until the pressure is below 10 bars

  • For Volvo trucks, no need to connect vent hose. Just turn vent lever counter clockwise to open position, until the pressure is below 10 bars. After venting, turn lever to closed position.


08.jpg

7. Payment

p8.png

Insert the fuel card in the payment terminal.

Choose dispenser n°3 / LNG.

Enter the correct PIN and mileage.


08.jpg

8. Refueling

  1. Press the ‘start’ button to start the cooldown process.

  2. The yellow ‘cooling’ light will light up. The cooldown is finished when the yellow light is switched off. The system is ready to refuel.

  3. Push the ‘refueling’ button at least once every 60 seconds. If not pushed within 60 seconds, refueling will be interrupted (the green light will start blinking faster to warn you).

  4. When the green READY light is switched off, refueling has ended.


LNG-10-new.gif

9. Remove the filling nozzle

p10.png
  • Pull the levers until they come to a stop (vent position). WATCH OUT: some gas will escape from the nozzle due to residual pressure.

  • Press the red button and pull the levers further back. WATCH OUT: If the nozzle sticks to the tank, wait for a few minutes, and use compressed air to defreeze the nozzle. WARNING: Never use tools or violence to remove the nozzle.

  • Don’t forget to put back the dust caps.

  • If connected, disconnect gas return hose. If needed, defreeze with compressed air.


10.jpg

10. In case of problems...

  • Push the intercom button and wait for a reply OR call +32 (0)800 999 03 (free number)

  • IN CASE OF EMERGENCY: Push the EMERGENCY STOP and call 112.


 
 

Refueling manual for LNG-powered vehicles. (KALLO)

Download a handy PDF version of the refueling manual for LNG-powered vehicles on the site of Kallo Antwerp (Belgium).

 
 
fuelcard-lng.jpg

LNG DRIVE Fuel Card

  • One monthly invoice overviewing all your refuels.

  • Extensive network at home and abroad.

  • Competitive prices.

Apply for your free Fuel Card for fueling LNG & CNG in our network!